What twenty S23 miners draw in an eight-hour shift

Twenty air-cooled S23s running for eight hours at 3.355 kW each consume 536.8 kWh. At 0.10 per kWh that shift costs 53.68 in the tariff currency. A 100 W difference per machine maintained for 30 days adds 1440 kWh across the row.

BITMAIN Antminer S23BITMAIN · S23

Firmware availability

No build for this exact model was verified in the site catalog on 22 November 2026. Check the full model and control board before downloading firmware.

See installation options

Factory rating

ModelAntminer S23
Hashrate305 TH/s
Wall power3355 W
Efficiency11 J/TH

Read the nameplate before choosing firmware

For the air-cooled S23 305T-10, 305 TH/s multiplied by 11 J/TH equals 3355 W. This cross-check catches a misplaced figure in a quotation. An S23 Hyd. has a different cooling system and its own specification. Keep its figures in a separate row.

A field check you can repeat

The same S23 can produce three plausible readings in a shift: instantaneous hashrate in its interface, an average at the pool and power at the distribution unit. Record the start and end of the sample. If the meter also feeds exhaust fans, note their load separately before quoting an efficiency figure for the miner.

What the meter will bill

ComparisonBasisResult
For one miner3.355 kW × 24 h80.52 kWh
For ten miners10 × 3.355 kW × 24 h805.20 kWh
For twenty miners20 × 3.355 kW × 8 h536.80 kWh

Sources

As of 22 November 2026

BITMAIN · S23 305T-10
BITMAIN · S23 Hyd.