Choose model and control board

ROI ASIC · Installation guide

Install VNISH with HashCore Toolkit

Use HashCore Toolkit 1.7.5 to install VNISH on a confirmed compatible Antminer or update an existing VNISH installation. For several miners, separate different hardware and starting firmware into groups. Check one miner from each group before repeating its installation route.

Your firmware package

Match the full model variant and control board, then compare the downloaded file's SHA-256 with the published value

Choose model and control board

Check before writing

Stock dated August 2026 or later is outside this standard installation route. Stop and contact support with the exact model, board and stock version. Do not upgrade or downgrade stock at random

Identify the current firmware and its date first. If you cannot confirm them, contact support before flashing

Prepare a group before installing on several miners

A shared model name is not enough to choose one file for a whole fleet. Prepare a local device list before selecting miners in Toolkit:

For example, an Antminer S21 AML group does not automatically include S21 Pro or a miner with another control board. If one unit's board or stock date is unknown, leave that unit out until its route is confirmed.

Get HashCore Toolkit 1.7.5

Toolkit is the installation tool, not the firmware. Download firmware only from this site's catalog. Run Toolkit on a device on the same trusted local network as the miner

Fill in the firmware fields

Firmware namevnish
Firmware versionVersion from the selected file name, without v

For example: …v1.3.6.tar.gz → 1.3.6; …v1.3.5.tar.gz → 1.3.5; …v1.3.4.tar.gz → 1.3.4. Firmware name remains vnish

Create a folder, for example C:\VNISH on Windows, and put the downloaded .tar.gz inside it without unpacking or renaming it. Select the folder, not the archive. An empty-looking folder picker is normal: it shows folders, not files

How to install firmware

BITMAIN stock firmware
Install firmware
VNISH already installed
Update firmware
  1. Open Toolkit, create New group, add your miner's IP or local range in Ranges and scan. Select the one confirmed miner
  2. Open Commands / All Commands and choose Install firmware / Update firmware. Do not upload our archive through the BITMAIN stock web updater
  3. Select the folder containing your archive. Enter vnish in Firmware name. In Firmware version, enter the version from that file name without v. Check the model before confirming.
  4. Confirm the operation locally and follow Operations until completion. Do not cut power or start another operation while writing
  5. Open the miner's web interface, check the installed version and your pools. Watch temperatures, hashrate and errors until stable before expanding to other miners

VNISH 1.3.6: On supported CVitek builds, VNISH starts automatically after a reboot.
Earlier versions: CVITEK / CV: after a restart, the firmware may need to be launched again using Toolkit → Restore firmware. This is not factory-stock recovery

Check your first miner

Before installation, save your pool and network settings and note the current hashrate and power use. After installation, check the firmware version, pool connection, accepted shares, temperatures, fans and hardware errors. Compare stable readings under the same conditions. If anything is abnormal, stop the test and check the cause before adding other miners.

Check the result before repeating it across a fleet

A completed task in Toolkit is the end of the installation operation, not the full check of a working miner. Record the following for the first device in each group:

If the checks pass, continue with the next planned group and keep its result separately. If a device is unreachable, reports errors or differs from the expected configuration, pause expansion and investigate that device. If the starting firmware or recovery procedure is unclear, confirm the route before writing. One successful miner does not validate every configuration in the fleet.

Contact our support

SSH / authentication error: stop, check local network access and the miner password configured in Toolkit. Keep the exact error log for support. An SSH error alone is not a reason to install newer stock

SD/USB recovery is a separate board-specific procedure. On AML with stock from September 2025 or later, USB unlocking may be needed for that recovery route, not as a blanket prerequisite for Toolkit installation

Third-party firmware can affect the manufacturer's warranty. Do not bypass security warnings, interrupt writing or use a file for a similar model

Contact our support

Previous versions remain available in the catalog. Firmware version must match the version in your selected file name, without the letter v